


Siemens PLC and Soft Starter
Data Sheets, Software and Tutorial Videos
1. Automatic door Siemens Logo tutorial. LAD FBD PLC tutorial
2. Controlling two pumps with one button Siemens LOGO PLC tutorial
3. Flashing light with two timers Siemens Logo tutorial
4. How to change Siemens LOGO 8 backlight color. PLCtutorial
5. How to display text messages with Siemens Logo
6. How to display text messages. Siemens Logo tutorial
7. Siemens PLC Multi Screen message texts in the LOGO
8. How to increase decrease counter value using cursor function keys.
9. How to set up a password for Siemens Logo – Tutorial
10. Motor forward reverse v.1 Siemens Logo tutorial. PLCtutorial
11. Motor forward reverse v.2 Simens Logo tutorial for Logo
12. One input controlling two outputs v.1 Siemens LOGO PLC
13. One switch ON OFF with time delay Siemens LOGO tutorial
14. Siemens Logo tutorial - how to create graph bar with data
15. Siemens LOGO tutorial - display menu with up_down buttons
16. Siemens Logo tutorial - menu_subscreens in LOGO display
17. Siemens LOGO tutorial Counters with multi-programme
18. Siemens Logo tutorial Motor Start Stop control circuit
19. Siemens Logo tutorial- Motor Start_Stop circuit (LAD)
20. Siemens Logo tutorial Scrolling text on Logo display
21. Simple auto changeover Siemens Logo tutorial
22. Simple car park system Siemens Logo tutorial.PLC tutorial
23.Simple_garden_lighting_control._siemens_logo_tutorial._plc_tutorial
24. Star Delta starter Siemens Logo
tutorial
25. 4 Pumps with Pressure Switch Alternate
26. Add a module Siemens PLC programming
27. Duty standby for pumps Siemens PLC
28. Flashing light with two timers Siemens PLC
29. LOGO 4 - 20 mA on the 0 - 10 V input
30. LOGO Analog amplifier gain offset
31. LOGO Analog basics Siemens PLC programming
32. LOGO Analog timer control Siemens PLC programming
33. LOGO Get connected IP addressing quick start
Siemens PLC
34. LOGO Simple setpoint limit Siemens PLC programming
35. LOGO Soft Comfort - Diagram Editor toolbar Siemens PLC
36. LOGO Timers 1 On-Delay Off-Delay On Off-Delay Retentive Siemens
37. LOGO Timers 2 Wiping Relay Edge triggered wiping Async Pulse Random Generator
38. LOGO Timers 4 Weekly timer Yearly timer Siemens PLC programming
39. Siemens PLC -Timers in LOGO - Weekly and Yearly timers
40. Analog Comparator for LOGO PLC
SIMATIC S7-1200

SIMATIC S7-1200 controllers by Siemens are the intelligent choice for compact automation solutions with extended communication options and integrated technology functions. They are available in standard and failsafe versions.

Be Flexible, Thanks to Networking Possibilities
SIMATIC S7-1200 controllers are the ideal choice when it comes to flexibly and efficiently performing automation tasks in the lower to medium performance range. They feature a comprehensive range of technological functions and integrated communication as well as especially compact and space-saving design.
1
SIMATIC S7-1200 CPUs
The modular SIMATIC S7-1200 controller is at the core of our offering for simple but highly precise automation tasks. The SIMATIC S7-1200 controller is modular and compact, versatile, a secure investment, and is perfectly suited to a whole range of applications.
2
SIMATIC S7-1200 Signal modules
The central processing units of the SIMATIC S7-1200 PLC are designed as Compact CPUs with integrated I/Os. Their modular design can be used to increase the configuration limits or to adapt the controller to new tasks: through mounting a Signal Board on the CPU or adding separate signal modules.
3
SIMATIC S7-1200 Special modules
Special modules enhance the application area of the whole system, e.g. for Codition Monitoring, integrated weighing technology, simulation of input signal or for extending the power reserve for the S7-1200 real-time clock by an additional battery board.
4
SIMATIC S7-1200 Communication modules
Communication modules increase the communication capabilities of the SIMATIC S7-1200 PLC through additional functions and interfaces. S7-1200 communication modules support serial communication, PROFIBUS, IO-Link, AS-Interface and several mobile standards.
S7-TIA Portal V16 Software Training Center
01- PLC
Lesson 01 - Configure Siemens S7-1200 PLC
Lesson 02 - Create PLC
Tags
Lesson 03 - Simple Ladder Logic and Monitoring
Lesson 04 - Math and implicit data type conversion
Lesson 05 - Conversion operations
Lesson 06 - Combine multiple math operations with Calculate
Lesson 07 - Global Data blocks (DB) Part 1
Lesson 08 - Global Data blocks (DB) Part 2
Lesson 09 - Create Watch Tables
Lesson 10 - Comments, Go to and Searching
Lesson 11 – Comparisons Function
Lesson 12 - Signal and RLO edge detection, Set and Reset
Lesson 13 - Function (FC)
Part 1
Lesson 14 - Function (FC)
Part 2
Lesson 15 - Function Block
(FB)
Lesson 16 - IEC
Timers
Lesson 17 - IEC Counters
Lesson 18 – Forcing
Lesson 19 - Cross Reference and Program Info
Lesson 20 - Uploading and Compare Offline-Online
Lesson 21 – Diagnostics
Lesson 22 - Connect Basic Panel HMI
02- HMI
Lesson 1- Create your first WinCC TIA Portal
HMI Project
Lesson 2- Use the Fixed Window Area and Template on Siemens HMI Tags
Lesson 3 - Configure a connection between Siemens HMI and S7-1500 PLC
Lesson 4 - Working with
Tags in Siemens
HMI Project
Lesson 5 - Configure your first HMI screen with a few basic objects
Lesson 6 - Configure Animation
session
Lesson 7 - Configure text dynamically changes
with tag
Lesson 8 -
Configure
a Pop-up screen
Lesson 9 -
Configure
a Slide-in screen
Lesson 10 -
Configure
Alarms
Lesson 11 -
Configure
Historical Trend
Lesson 12 -
Configure
Recipe
Lesson 13 - Configure User Administration
Lesson 14 – Scripting
Function
Lesson 15 - Project and Global Library (FB)
Lesson 16 - Multi-Language Project
Lesson 17 - Ethernet Project Transfer
Lesson 18 - USB Stick Project Transfer
Lesson 19 - Media Player and File viewer
Lesson 20 - Cross References
Download Center

3RW 30
SIRIUS 3RW30 soft starters reduce the motor voltage through variable phase angle control and increase it from a selectable starting voltage up to the mains voltage within the ramp time. They limit the starting current and torque, reduces the stress on the connected equipment, resulting in lower wear and therefore longer periods of trouble-free production.

3RW 40
SIRIUS 3RW40 soft starter comes with additional integrated functions such as settable current limiting, motor overload and intrinsic device protection, and optional thermistor motor protection. The higher the motor rating, the more important these functions become because they make it unnecessary to purchase and install protection equipment (such as overload relays).
Internal intrinsic device protection prevents thermal overloading of the thyristors and the power unit defects this can cause. As an option, the thyristors can also be protected against short-circuiting with semiconductor fuses.

3RW 52
SIRIUS 3RW52 General Performance soft starters are the ideal solution for standard applications. With ideal 3-phase motor control, they cover the performance range from 5.5 kW to 560 kW (at 400 V).
Optional HMI modules, plug-in communications modules (PROFINET, PROFIBUS, EtherNet/IP and Modbus) and either an analog output or thermistor motor protection provide maximum flexibility.
With their modern hybrid switching technology, the SIRIUS 3RW52 soft starters offer efficient switching for long-term, energy-saving use
DATA SHEETS
3RW 30
3RW 40
3RW 52
Rated Current: 143 A
Rated Power at Direct Circuit: 75 Kw
Rated Power at Inside Delta Circuit: 132 Kw
Rated Current: 171 A
Rated Power at Direct Circuit: 90 Kw
Rated Power at Inside Delta Circuit: 160 Kw
Rated Current: 210 A
Rated Power at Direct Circuit: 110 Kw
Rated Power at Inside Delta Circuit: 200 Kw
Rated Current: 250 A
Rated Power at Direct Circuit: 132 Kw
Rated Power at Inside Delta Circuit: 250 Kw
Rated Current: 570 A
Rated Power at Direct Circuit: 315 Kw
Rated Power at Inside Delta Circuit: 560 Kw
Equipment Manuals - Siemens e-Manuals

1
3RW30 and 3RW40
This manual contains fundamental information and practical tips for using SIRIUS soft starters. The SIRIUS 3RW30 and 3RW40 soft starters are electronic motor control devices that facilitate optimal starting and stopping three-phase induction motors.
The manual describes all of the functions of the SIRIUS 3RW30 and 3RW40 soft starters.
2
3RW52
This manual contains fundamental information and practical tips for using SIRIUS soft starters. The SIRIUS 3RW52 soft starters are electronic motor control devices that facilitate optimal starting and stopping three-phase induction motors.
The manual describes all of the functions of the SIRIUS 3RW52 soft starters.







